2 edition of wedge hot-film anemometer in supersonic flow found in the catalog.

wedge hot-film anemometer in supersonic flow

John M. Seiner

wedge hot-film anemometer in supersonic flow

by John M. Seiner

  • 102 Want to read
  • 2 Currently reading

Published by National Aeronautics and Space Administration, Scientific and Technical Information Branch, For sale by the National Technical Information Service] in Washington, D.C, [Springfield, Va .
Written in English

    Subjects:
  • Film coefficients (Physics),
  • Anemometer.,
  • Aerodynamics, Supersonic.,
  • Base flow (Aerodynamics)

  • Edition Notes

    StatementJohn M. Seiner.
    SeriesNASA technical paper -- 2134.
    ContributionsUnited States. National Aeronautics and Space Administration. Scientific and Technical Information Branch., Langley Research Center.
    The Physical Object
    Pagination54 p. :
    Number of Pages54
    ID Numbers
    Open LibraryOL18025509M

    Measuring Airflow With a Hot Wire Anemometer. The principal of a hot wire anemometer is based on a heated element from which heat is extracted by the colder impact airflow. The temperature of the hot wire is kept constant via a regulating switch, and the current (amp draw measured internally) is directly proportional to the air velocity. Hot-film sensors consist of a very thin film of platinum (typically 1 #m) deposited by sputtering on a quartz support. The support is usually a cylinder (with a typical diameter of /tm) or sometimes a wedge or a cone. Hot films are used mostly in liquids. An additional quartz coating then .

    The relationship between the rate of heat transfer from a hot-film, that is proportional to the square of the anemometer bridge voltage, and wall shear stress for a thin-film gauge is given by. E 2 - A 2 =kt w 1/3. where the constant, A is almost equal to the output voltage of the anemometer at zero-flow (=E 0). Typical calibration for a hot. Abstract. In this study, a micromachined hot film anemometer, placed on a pressure stable LTCC-substrate, is presented to measure the different injection quantities, needed in modern direct injection (Dl) system for optimum by: 1.

    1. J Biomech Eng. Aug;(3) Flush-mounted hot film anemometer accuracy in pulsatile flow. Nandy S, Tarbell JM. The accuracy of a flush-mounted hot film anemometer probe for wall shear stress measurements in physiological pulsatile flows was evaluated in fully developed pulsatile flow in a rigid straight by: 8. review of methods for flow velocity measurement in wind tunnels 65 In Fig.8b calibration curve fo r the test section of the water cavitation tunnel T is shown [].


Share this book
You might also like
Essay on patriotism

Essay on patriotism

Copleys Watson and the shark and aesthetics in the 1770s

Copleys Watson and the shark and aesthetics in the 1770s

World Conference of the United Nations Decade for Women

World Conference of the United Nations Decade for Women

Texas Public School Organization and Administration

Texas Public School Organization and Administration

The 2000 Import and Export Market for Cutlery in Portugal

The 2000 Import and Export Market for Cutlery in Portugal

260.1-1993 American National Standard Letter Symbols for Units of Measurement (SI Units Customary Inch-Pound Units, and Certain Other Units

260.1-1993 American National Standard Letter Symbols for Units of Measurement (SI Units Customary Inch-Pound Units, and Certain Other Units

Operating cost statistics of automobiles and trucks

Operating cost statistics of automobiles and trucks

Report of the majority of the Committee on Banks

Report of the majority of the Committee on Banks

Christmas greeting

Christmas greeting

Portrait of the bullfight

Portrait of the bullfight

Revision of the Indo-Pacific fish family Caesionidae (Lutjanoidea), with descriptions of five new species

Revision of the Indo-Pacific fish family Caesionidae (Lutjanoidea), with descriptions of five new species

The census of distribution

The census of distribution

Mathematical statistics

Mathematical statistics

Mutual aid, a factor of evolution

Mutual aid, a factor of evolution

The student edition of MathCAD

The student edition of MathCAD

The 2000 Import and Export Market for Motorless Trailers in The Middle East (World Trade Report)

The 2000 Import and Export Market for Motorless Trailers in The Middle East (World Trade Report)

Employment and employee compensation in the 1967 input-output study

Employment and employee compensation in the 1967 input-output study

A guide to assessing needs

A guide to assessing needs

Wedge hot-film anemometer in supersonic flow by John M. Seiner Download PDF EPUB FB2

Wedge hot-film anemometer in supersonic flow. Washington, D.C. National Aeronautics and Space Administration, Scientific and Technical Information Branch ; [Springfield, Va.: For sale by the National Technical Information Service], (OCoLC) Material Type: Government publication, National government publication: Document Type: Book.

properties of wedge-shaped hot-film anemometry probes and to provide a means for interpreting their voltage signal in terms of the physical variables.

The supersonic properties of the wedge hot-film probe were established by posi- tioning a wedge probe at the exit. Repeated measurements have shown that at mean velocities U > m/s, gauge temperature T wthe heat losses Q fr.c, Q r, and Q can be ignored, the more so if the gauge is individually calibrated.

Q fr.c depends on the heat transfer coefficient α, wedge hot-film anemometer in supersonic flow book surface area A, the angle β subtended by the velocity vector direction and the. An anemometer for a study of wind gusts.

([Ann Arbor], ), by Robert Henry Sherlock and Melville Bigham Stout (page images at HathiTrust) The wedge hot-film anemometer in supersonic flow / (Washington, D.C. National. An anemometer is a device used for measuring wind speed and is also a common weather station instrument.

The term is derived from the Greek word anemos, which means wind, and is used to describe any wind speed instrument used in first known description of an anemometer was given by Leon Battista Alberti in   MTP - Hot Wire Thermo-Anemometer with Air Flow (product video presentation) - Duration: Digital Measurement Metrology, a Trescal Company views Hot wire and hot film sensors are used for measurements of fluctuations in the wind.

Such anemometers are in competition with both mechanical and sonic anemometers. At least some of the mechanical sensors are more stable in calibration, and less by: A hot film anemometer for the Martian atmosphere, described by Dominguez et al in Ref. [15], as part of the Rover Environmental Monitoring System (REMS), was embarked on the Mars Science.

Hot-Film Sensors. The hot-film sensor is essentially a conducting film on a ceramic substrate. The sensor shown in Figure 2 is a quartz rod with a platinum film on the surface. Gold plating on the ends of the rod isolates the sensitive area and provides a heavy metal. Hot-Film Constant Voltage Anemometer.

The multi-channel Hot-Film Constant Voltage Anemometer (HF-CVA) was developed specifically for making simultaneous shear stress measurements using hot-film with the HW-CVA, the HF-CVA eliminates problems associated with the use of conventional anemometry, i.e.

constant current anemometer (CCA) and constant temperature anemometer (CTA). Supersonic diffusers. See also what's at your library, or elsewhere. Broader term: Aerodynamics, Supersonic; Filed under: Supersonic diffusers Performance of a short annular dump diffuser using suction-stabilized vortices at inlet Mach numbers to / (Washington: National Aeronautics and Space Administration, Scientific and Technical Information Office ; Springfield, Va.

A wide variety of hot film anemometer options are available to you, There are 17 suppliers who sells hot film anemometer onmainly located in Asia. The top countries of supplier is China, from which the percentage of hot film anemometer supply is % respectively.

John M Seiner has written: 'The wedge hot-film anemometer in supersonic flow' -- subject(s): Aerodynamics, Supersonic, Anemometer, Base flow (Aerodynamics), Film.

Air Velocity Measurement with Hot-Film Anemometers Operation Principle The E+E air velocity measuring devices employ E+E sensors manufactured in state-of-the-art thin film technology and are based on the thermal anemometric measurement principle. An E+E air velocity sensor consists of two resistors deposited on a thin glass Size: KB.

Constant temperature method The bridge arrangement along with the anemometer has been shown in diagram. The anemometer is kept in the flowing gas stream to measure flow rate. A current is initially passed through the wire. Due to the gas flow, heat transfer takes place from the sensing wire to the flowing gas and this tends to change the temperature and hence the resistance of the wire.

Calibration curve of a constant-temperature anemometer (DISA type 44D0l) in water with a hot-film transducer of the type 55A81 at two different overheating ratios a. V b-ridge voltage, U flow velocity. Anemometer' AL. From the_ Transducer-- -- ransducer pressure tank ­ jjManometer.

Trnsducer Glas s tube [1-izz'" Transducer -__ _ IL - --Pump File Size: KB. Hot-film anemometer. From AMS Glossary. Jump to: navigation, search. hot-film anemometer. Similar to a hot-wire anemometer, with the exception that the sensing element is a thin film of conductive material on the surface of a nonconductive rod.

Flow basics. Version 8/9 2. Flow formulas. Volume flow is the direct combination of the surface the A, fluid is streaming through with its average velocity.

Volumetric flow rate = average velocity ∙ flow surface. V [m 3 / s] = v [m / s]⋅ A [m 2] To calculate the standard volume flow it is necessary to measure actual pressure and File Size: KB.

mass air flow sensors (maf) hot film or hot wire anemometer application guide mass air flow (maf) sensor vehicle engine eng. mustang l m f0vfbaa, ab, ac 6 cylinder contour l from 5/3/99 f6dfbea, f6dz-ea File Size: 1MB.

The Design and Use of a Temperature-Compensated Hot-Film Anemometer Syst em for Boundary-Layer Flow Transition Detection on Supersonic Aircraft Author: Harry R.

Chiles Subject: NASA TM Keywords: Flow transition; Hot-film anemometer; Telemetry output Created Date: 2/22/ AM. N2 - Temporal and spatial resolutions of hot-film anemometer (CTA) and laser-Doppler anemometer (LDA) were studied on the unsteady turbulent flow generated behind a prosthetic heart valve under pulsatile flow condition.

Frequency response was lower in the LDA measurements (approximately 1 kHz) than in the CTA ones (approximately 6 kHz).Cited by: 2.An Anemometer is used to measure air speed with some versions also measuring air flow. There are different types of anemometers depending on how you are planning to use them and your application.

If you want to measure wind speed outside and you are not concerned about wind direction then a Cup anemometer would be the meter you are looking for.Publications by Aeroacoustics Group Reduction of Noise Generated by a Half-Open Weapons Bay Google Scholar M.

Panickar, N. Murray, B. Jansen, M. Joachim, R. Birkbeck, C. Kannepalli & N. Sinha Journal of Aircraft, (in print). The Contributions of John M. Seiner Towards Aeroacoustic Facilities and Experimental Techniques Google ScholarB. J. Jansen, International Journal of Aeroacoustics, [ ].